2023-03-23

Membrane Parameters

Product

Part number

Active Area ft2(M2)

Feed Spacer Thickness (mil)

Permeate flow rate gpd (m3/d)

Stabilized salt rejection (%)

Minimum salt rejection (%)

BW30-365

80773

365 (34)

34

9,500 (36)

99.5%

99.0%

BW30-400

98650

400 (37)

28

10,500 (40)

99.5%

99.0%

 

Same point: Salt rejection rate is the same 99.5%

Difference:

BW30-365

  • Feed spacer thickness is larger, which can lessen the impact of fouling.
  • Suitable for systems operating on challenging feed streams, where reliable pretreatment is not an option, or where maximum cleanability delivers value.
  • Membrane price lower, which can save replacing cost.

BW30-400

  • Feed spacer thickness is smaller, so compare with BW30-365, it more like to fouling and high rejection. This model will be choose when highest quality permeate is required.
  • The active area and permeate flow is larger, which can deliver high flow.
  • Membrane price high. High initial investment and consumable replacement costs.

 