Acidic Electrolyzed-oxidizing Water(AEOW) Generator
Basic Configuration:
- Water Outlet Fittings: PP+PE, specialized in acid and alkali resistance
- Electrolyzer: Imported ion membrane
- Metering Pumps: Adjustable stroke and frequency
- Switching Power Supply: Specialized for medical devices
- Import isolation transformers and power filters
- Salt Water Tank: PE material, corrosion resistant
- Adjustable Power Supply: Adjustable output voltage and current, meeting the operation requirements of the electrolyzer
Share to
Introduction Of AEOW
- Equipment Composition and Core Configuration
The generator consists of a host and a NaCl solution supply device, with simple installation and operation; the NaCl solution supply device is equipped with a corrosion-resistant precision metering pump (capable of automatic salt addition); it adopts a PLC fully automatic control program and a ≥7-inch color touch operation screen, integrating water circuits and electrical controls into one system. - Production Process and Capacity
It employs a continuous electrolysis process, enabling continuous production of AEOW. - Advantages
It strictly complies with GB28234-2020 Safety and Health Standards; AEOW has the advantages of quickly and effectively killing microorganisms, leaving no residual poison, and being conducive to environmental protection. - Applications
Applicable for disinfection in various aspects, including medical devices and supplies, skin and hand hygiene, surface disinfection, surgical site preparation, dining utensils, and food processing.
Features of AEOW
01
One-Click Water Dispensing Function: By pressing the water dispensing button, the AEOW obtain could be conveniently.
02
Online monitoring the pH value of produced water, conductivity of inflow water, status of the electrolyzer, liquid level of the NaCl solution supply device, and fault alarms.
03
Excess-Standard Water Discharge Function: When the pH value of acidified water is unqualified (pH < 2 or pH > 3), it will be automatically discharged through a discharge valve to prevent the use of substandard water.
04
Fault records can be queried by date.
05
Pressure monitoring, inflow and effluent flow monitoring
06
Temperature Control Protection: When the temperature exceeds the specified limit, the main power supply will be automatically disconnected.
Specification of AEOW
Name | Model Specification | Generation level | |
Acidic Water | Alkaline Water | ||
Acid Oxidation Potential Water Generator | MOL-AEOW-A | 1000 mL/min | 1000 mL/min |
2000 mL/min | 2000 mL/min | ||
3000 mL/min | 3000 mL/min | ||
4000 mL/min | 4000 mL/min | ||
5000 mL/min | 5000 mL/min | ||
6000 mL/min | 6000 mL/min | ||
7000 mL/min | 7000 mL/min | ||
8000 mL/min | 8000 mL/min | ||
9000 mL/min | 9000 mL/min | ||
10000 mL/min | 10000 mL/min |
Get Free Quote
Please fill in the following form, we will respond your request in 24 hours.