Industrial 25TPH Reverse Osmosis Pure Water Treatment System

This system is a 25T/H pure water system designed based on client raw water conditions, water quality requirements, installation room size conditions, and relevant national standard, using the most advantaged reverse osmosis technology.

Raw water condition

  1. Raw water:Local tap water  Conductivity ≤500us/cm@25℃
  2. Temperature requirement:5~40℃
  3. Inlet pressure:0.1-0.4MPa 
  4. Inlet flow::≥50T/H

Technical specification

Control systemPLC + HMI auto and manual 
Automatic protectionhydropenia, power off, overload, overflowing 
Ro membraneDOW membrane USA original
MaterialSS304 + FRP+UPVC
Production rate25000L/H
Feeding waterUnderground water
CertificationISO 9001
Recovery rate70%
Desalination rate98-99%

Working flow

Raw water —Mutimedia filter —Activated carbon filter —Antiscalant dosing device —5μm security filter —high pressure pump —Reverse Osmosis system —Pure water tank(By client)

Features of reverse osmosis RO water system

Two stage of pretreatment filters, include multimedia filter, activated carbon filter to improve the inlet water quality.
The pretreatment filters are automatic controlled by automatic control valve.
Economic materials and configuration to save cost.
Modularization, full automatic control.  
Running and maintenance cost is low .